Features

  • ZVS technology to reduce power dissipation
  • Universal AC input / Full range
  • Built in active PFC circuit compliance to EN61000-3-2
  • Protectioins:Short circuit/Over load/Over voltage/Over temperature
  • Free air convection for 300W and 350W with 23.5CFM forced air
  • High power density 5.6w/in3
  • Active AC surge current limiting
  • U-bracket low profile: 38mm


    Case details: 235.2 x 101.5 x 38mm

 

 

Specification

Voltage range
90 ~ 264VAC 2A/230VAC
Frequency range
47 ~ 63Hz
Power factor (typ.)
3.3V: 0.94/230VAC ; 5V~48V: 0.95/230 VAC, 0.98/115VAC at full load
AC current (typ.)
4A/115VAC 2A/230VAC
Inrush current (typ.)
22A/115VAC 44A/230VAC
Leakage current
<2mA / 240VAC
Voltage tolerance
¡À2.0%
Line regulation
¡À0.5%
Setup, rise time
2000ms, 100ms/230VAC 4000ms, 100ms/115VAC at full load
Hold time (typ.)
3.3V: 12ms/230VAC ; 5V~48V: 16ms/230VAC 16ms/115VAC at full load
Over load protection
3.3V & 5V: 105~120% rated output power; 12V~48V: 105~130% rated output power
Protection type:Constant current limiting, recovers automatically after fault condition is removed
Over voltage protection
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over temperature protection
80¡ãC (3.3V~48V)(TSW1:Detect on heatsink of power transistor); 80¡ãC¡À5¡ãC(3.3V~15V),75¡ãC¡À5¡ãC(24V,48V)
(TSW2:Detect on heatsink of power diode) Protection type:Shutdown o/p voltage with auto recovery
Working temp.
-10~+65¡ãC (refer to output load derating curve)
Working humidity
20 ~ 90% RH non-condensing
Storage temp., humidity
-40~+85¡ãC, 10~95% RH
Temp. coefficient
¡À0.03%/¡ãC (0~45¡ãC)
Vibration
10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X,Y,Z axes
MTBF
106.3K hrs min. MIL-HDBK-217F (25¡ãC)
Safety standards
UL60950-1, TUV EN60950-1 approved
Withstand voltage
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation resistance
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI conduction & radiation
Compliance to EN55022 (CISPR22) Class B
Harmonic current
Compliance to EN61000-3-2,-3
EMS immunity
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A







350W Series

Order Code
DC Voltage
Rated current
Current range (convection)
Current range(23.5CFM fan)
Rated power  (convection)
Rated power(23.5CFM fan)
Ripple & Noise (max)
Voltage adj. range
Load regulation
BL-LPST-350-12
12V
29.2A
0~25A
0~29.2A
300W
350.4W
100mVp-p
10.8~13.2V
¡À1.0%
BL-LPST-350-24
24V
14.6A
0~12.5A
0~14.6A
300W
350.4W
150mVp-p
21.6~26.4V